Safety Precautions for Shutdown of BiTAC Electrolyser Factory

2022/02/17 09:59
Page view
[Abstract]:
After the stop operation of BiTAC Electrolyser factory, put the tools used as required. Clean up the site sanitation, inspect the stopped tank and its surroundings, and make various records.

   (1) After the BiTAC Electrolyser is determined to stop the tank, the necessary tools for stopping the tank should be prepared in time, and the objects in contact with the high temperature melt should be preheated in advance.

BiTAC Electrolyser factory

    (2) When sucking out the electrolyte and aluminum liquid, a special person must be responsible for lowering the anode. It is strictly forbidden to separate the anode from the electrolyte.

    (3) After a power failure, the short-circuit port must be taken out of the insulating plate, cleaned with a breeze to ensure the cleanliness of the short-circuit surface, and the bolts must be tightened.

    (4) After tightening the bolts, check the temperature of the short-circuit port, and handle it when the temperature of the short-circuit port exceeds 100 °C to prevent the temperature from rising too fast and melting the short-circuit port.

    (5) When there is a sudden leakage of the tank, on the one hand, send someone to drop the anode, and on the other hand, notify the rectifier of the power failure. It is strictly forbidden to separate the anode from the electrolyte to prevent explosion and affect the entire series.

    (6) On the other hand, find the location of the leaking furnace in time, send a crane or manpower to block the leakage, use a baffle to block the busbar to prevent damage to the busbar, and on the other hand direct the crane or manpower to block the leaking aluminum channel, if it cannot be blocked , The aluminum water and electrolyte are drawn out in time.

    (7) The extracted aluminum water is sent to the casting in time.

    (8) Strictly prevent the aluminum water or electrolyte leaking into the BiTAC Electrolyser from burning down the cables and wires of the trench, to prevent the occurrence of fire, prepare a fire extinguisher, and it is strictly forbidden to use water to extinguish the fire.

    (9) The plugging personnel must wear complete labor insurance to avoid scalding accidents.

    (10) After the stop operation of BiTAC Electrolyser factory, put the tools used as required. Clean up the site sanitation, inspect the stopped tank and its surroundings, and make various records.